SPECIALIZING IN B2B SALES, WE PROVIDE ADVANCED SOLAR SOLUTIONS EXCLUSIVELY FOR COMMERCIAL CLIENTS AND INSTALLERS. WITH STRATEGICALLY LOCATED WAREHOUSES, WE ENSURE DISPATCH WITHIN 2 TO 3 WORKING DAYS, STREAMLINING YOUR SOLAR PROJECT TIMELINES EFFICIENTLY. TRUST IN OUR EXPERT-DRIVEN, RELIABLE SERVICE. VOIP: +27 (11) 568 0429
SPECIALIZING IN B2B SALES, WE PROVIDE ADVANCED SOLAR SOLUTIONS EXCLUSIVELY FOR COMMERCIAL CLIENTS AND INSTALLERS. WE ENSURE DISPATCH WITHIN 2 TO 3 WORKING DAYS. VOIP: +27 (11) 568 0429
Skip to content

Automatic Voltage Switch, Three Phase, Excl Contactor

SKU AVS-3P-0-MICRO
R 3,797.00
incl VAT
Availability: Translation missing: en.general.icons.icon_check_circle icon 8 in stock, ready to be shipped

Notify me when back in stock

Automatic Voltage Switch, Three Phase, Excl Contactor

The Sollatek Automatic Voltage Switcher is built to protect inverters from harmful grid fluctuations. Using a microprocessor, the AVS 3P micro protects your inverter from harmful grid conditions such as over voltage, under voltage and even power-back surges that are very common with load shedding.

The AVS 3P micro is compatible with any size contactor, making it perfect for any size three phase inverter. The five voltage indicators will indicate if the grid is withing the acceptable values that have been selected.

TIMESAVE™ function checks the duration of OFF time from the mains. If the mains have been off for more than 3 minutes, then it will reconnect the mains withing 30 seconds instead of the standard 3 minutes. This means your batteries will start charging almost immediately while ensuring your system is still protected.

The AVS 3P micro provides the following protection:

  • High voltage - High voltages from the grid can damage internal components
  • Low voltage - Under voltages from the grid could damage internal components by not providing the components with sufficient voltage
  • Class III voltage spikes/surges - Small voltage spikes experienced when there is faults on the grid lines
  • Power-back surges - High power surges when grid comes back online, such as after loadshedding

Please note: A contactor of appropriate size vs inverter is required for this device to fully operate. The contactor must by 230V and not exceed 16A operating current.

 

This product must be installed by a qualified electrician/technician. All installations must adhere to local wiring regulations and standards. SegenSolar will not be held liable for any product malfunctions as a result of incorrectly installed systems.